| M2817 |
 |
Conductivity Transmitter |
| |
|
|
 |
- direct pipe installation
- measurement range: 0...20µS to 0...20mS
- power supply 24VAC or DC, galvanically isolated
- 4...20mA current output, galvanically isolated
- polypropylene case
- qualified for food industry / sterilizable cells
- optional: temperature compensation to 80ºC
|
|
|
Technical description
The M2817 conductivity transmitter is packed in a
polypropylene case. Different conductivity electrodes in
stainless steel and graphite are available. Â
The conductivity transmitter is
suitable for water, waste water or ultrapure water
conditioning in continuous or batch-type operating
modes, for liquid chromatography or for general chemical
process monitoring.
An optional temperature compensation up to 80ºC is
available. This can be made with a factory programmed
value or with a temperature sensor assembled in the
cell.
The measure signal is available as a galvanic isolated
output of 0...20mA, 4...20mA or 0..10V DC.
The M2817 can be supplied by
either 24VAC or DC. The power supply is galvanically
isolated to the electrodes and output signal.
Supply lines and all other lines, either from or to the
conductivity transmitter, are protected by internal
noise limiters against HF-noise.
A cable of either 2m or 5m is used to connect the M2817.
|
| |
|
| News |
 |
|
|
|
|
|
|
|
|
08.10.08 |
new option: Tees PP D=35mm for conductivity cells ¾" |
|
|
|
|
|
|
|
|
|
|
|
|
|
Top |
|
|